Nipples may be used for inline applications, critical flow orifices, flow reduction, gas/liquid separators, needle valve replacement, gas mixing, and pressure reduction. Optically measured holes are not guaranteed to meet a specified flow rate.
Specifications
Diameter
6.35mm x 6.35mm (1/4″NPT x 1/4″)
Centering
±0.250mm (±0.00984″)
Orifice Diameters
1 – 1000µ (0.0000394″ – 0.0394″)
Material
Stainless Steel (SS-303)
Optically Measured Tolerances
Diameter |
Tolerance +/- |
2 µm |
40% |
3 - 5 µm |
20% |
6 µm |
15% |
7 - 149 µm |
10% |
150+ µm |
5% |
Flow Calibrated Tolerances
Diameter |
Dia +/- |
Flow +/- |
1 µm |
40% |
80% |
2 µm |
20% |
40% |
3 µm |
15% |
30% |
4 - 11 µm |
10% |
20% |
12 - 149 µm |
5% |
10% |
150 µm+ |
2.5% |
5% |