EMCO ISA 1932
EMCO ISA 1932 Nozzle with Carrier Rings Series in all Welded Construction DES
Principle:
- EMCO ISA 1932 nozzles are used as primary elements in flow measurement of steam, liquid, and gas according to the differential pressure principle.
Design and calculation standards :
- ISO 5167-3
- Sizes : DN 50 - 500
- Pressure rating : PN 10 - 400, 150 - 2500 lbs
- β (d/D) : 0.3 < β < 0.8
- Material : Carbon steel P250GH, AISI 316, 16Mo3, 13CrMo4-5, 10CrMo9-10, WB 36, X20CrMoV121, P91, P92, other materials on request
- Mounting style : Weld ends according to DIN 2559 or ANSI B16.25
- Pressure taps : Ø 21.3 mm, 24 mm, 26.9mm, 3/8", 1/2" BSP, 1/2" NPT
- Tap lengths : 150 mm, others on request.
- Tap location : At least 45° apart. For steam flow in a horizontal pipe : 180° To be stated with order.
- Tappings : Single pressure tappings
- Tap lengths : 150 mm, others on request
- Tap location : At least 45 degrees apart, for sizes below DN 150. To be stated with order.
Technical Data
- Accuracy : 0,8 % for β < 0,6, (2β - 0,4) % for β > 0,6 (according to ISO 5167-3)
- Pressure loss : Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured
- Limits for Re. No. : 2 x 10 4 < ReD < 1 x 10 7 according to ISO 5167-3
- Accessories
- Shut-off valves and condensing chambers for steam flow measurement
Overall Dimensions
All Dims in mm
Upstream length | Total length | Upstream length | Total length | ||
---|---|---|---|---|---|
DN | Ø Inner pipe | ISO 5167 | ISO 5167 | DIN 19215 | DIN 19215 |
50 | 45 - 57 | 115 | 230 | 150 | 250 |
65 | 58 - 72 | 145 | 290 | 180 | 300 |
80 | 73 - 90 | 180 | 360 | 230 | 350 |
100 | 91 - 112 | 225 | 450 | 280 | 400 |
125 | 113 - 137 | 275 | 550 | 350 | 500 |
150 | 138 - 162 | 325 | 650 | 400 | 600 |
(175) | 163- 187 | 375 | 750 | 470 | 700 |
200 | 188 - 225 | 450 | 900 | 570 | 800 |
250 | 226 - 275 | 550 | 1100 | 690 | 1000 |
300 | 276 - 325 | 650 | 1300 | 820 | 1200 |
350 | 326 - 375 | 750 | 1500 | 950 | 1400 |
400 | 376 - 425 | 850 | 1700 | 1050 | 1500 |
450 | 426 - 475 | 950 | 1900 | 1200 | 1700 |
500 | 476 - 550 | 1100 | 2200 | 1370 | 2000 |
600 | 551 - 650 | 1300 | 2600 | 1500 | 2000 |
700 | 651 - 750 | 1500 | 3000 | 1500 | 2000 |
800 | 751 - 850 | 1700 | 3400 | 1500 | 2000 |
900 | 851 - 950 | 1900 | 3800 | 1500 | 2000 |
1000 | 951 - 1100 | 2200 | 4400 | 1500 | 2000 |
Horizontal Installation Requirements
Vertical Installation Requirements
- Marking:Main tube marked with flow direction. Taps with "+" and "-".
- Other data on attached nameplate.
- EMCO ISA 1932 nozzle with condensing chambers for steam flow measurement in a horizontal or vertical pipe line.
Works with:-
Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.
MultiVariable Transmitters :- IMV25, IMV30
Download Datasheet ISA 1932 Nozzle with Carrier Rings Series in all Welded Construction
Download Manual (Not Available)